Ventilator circuit disconnection

Educational use only. Not clinically reviewed

63-year-old man for Ventilator disconnect alarm with falling oxygen reserve. About 7 simulated minutes.

What you will practise

  • Recognize lost delivered ventilation despite unchanged commanded settings.
  • Call for help and record immediate alternative oxygenation and ventilation intent while reserve is falling.
  • Trace the patient, airway, circuit, ventilator, and gas source while keeping other causes open.
  • Record restoration of circuit continuity and established ventilator support.
  • Prove delivered breaths and reassess oxygenation, ventilation, pressures, capnography, and circulation.

Review and sources

Not clinically reviewed. No clinician has signed this scenario.

  • Goodfellow LT, Miller AG, Varekojis SM, et al. AARC Clinical Practice Guideline: Patient-Ventilator Assessment. Respir Care. 2024;69:1042-1054.
  • U.S. Food and Drug Administration. Lung Therapy Component Recall: Baxter Healthcare Corporation Recalls Certain Volara System Single-Patient Use Circuits and Blue Ventilator Adapter Assemblies Due to Disconnection Risk That May Prevent Proper Ventilation. 2024.
  • U.S. Food and Drug Administration. Philips Respironics Issues Voluntary Recall Notification/Field Safety Notice for the V60 Ventilator Product Family. 2022.
  • Görges M, Markewitz BA, Westenskow DR. Improving alarm performance in the medical intensive care unit using delays and clinical context. Anesth Analg. 2009;108:1546-1552.